Philips Healthcare · Model SyncVision
Angio + Vessel Enhancement - provides clarity in visualizing vessels potentially reducing the number of required views during diagnosis or therapy Quantitative Coronary Analysis - automatically calculates lumen dimensions and stenosis in real time IVUS Co-Registration Localization - co-registers the location of the IVUS image on the angiogram and provides easy length and area measurements with a manual IVUS pullback Simplifies Vessel Sizing/Measurement - provides easy length measurement with manual IVUS pullback and area/diameter measurements for accurate stent sizing Angio + Device Positioning - provides enhanced visualization of device position within the vessel and is designed to help reduce risk of geographic miss Healthy-to-Healthy Landing Zones - intravascular ultrasound guidance helps to confirm healthy-to-healthy landing zones.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The medical imaging is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.