Philips Healthcare · Model Oxypleth Pulse Oximeter
Alert Limits - Operator selectable, automatic or menu selected High and Low limits for SpO2 and Pulse Rate, continuously displayed. Visible alert is immediate, audible alert occurs 10 seconds after violation of set limit. Two-Minute Silence - When Audio key is pressed, audible alerts are deactivated for two minutes. Indicated by illuminated 2-Minute LED. Audio Off - Press and hold Audio key for three seconds to deactivate audible alerts. Indicated by flashing Audio Off LED. Trend Memory - 24-hour trend memory capacity, battery backed. On-screen 12 hr., 8 hr., 2 hr., or 30 minute graphical and histogram displays. User defined Events are stored in memory. Trend and histogram information can be printed. NovaCARD Data Archive System - Compatible with NovaCARD, a Computer Archive, Recall and Display system for storing, printing, and analyzing patient data.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No saturation / pulse value, "pulse search", low signal quality, implausible values.
Root cause: Worn or wrong SpO2 sensor, a damaged cable, poor site / perfusion, or motion.
Symptoms: Reading drops when the cable is moved, sensor not recognised.
Root cause: Broken conductors in the sensor / extension cable, or a worn connector.
Symptoms: SpO2 consistently biased vs an arterial reference.
Root cause: Sensor degradation, or a monitor calibration / module fault.
Symptoms: No or quiet audible alarm.
Root cause: Speaker or audio-board fault - a safety-critical failure.
Symptoms: Short battery run time, will not power on.
Root cause: Aged battery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| SpO2 sensor (reusable / disposable) | Frequent wear item | $$ | Easy |
| Pulse-oximetry extension cable | Frequent wear item | $$ | Easy |
| Battery | Periodic replacement | $$ | Fairly easy |
| SpO2 module / board | Major service part | $$$ | Moderate |
| Alarm speaker / audio board | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.