Philips Digital Mammography Sweden AB · Model L50
Philips MicroDose SI (Model: L50) is intended to produce radiographic images of the human breast for the purpose of diagnostic and screening mammography. The system is intended to be used in the same clinical applications as traditional film-based mammography systems.
Intended use: A stationary assembly of devices designed to generate x-ray images of the breast using digital techniques for image capture and display. It is designed specifically to compress the breast during imaging and is intended to visually evaluate the anatomy and function of blood and lymphatic vessels within the breast. Often referred to as a digital mammography system (DMS) it is typically used for breast cancer screening or during biopsy procedures (e.g., placement of biopsy markers, stereotactic biopsy). It is designed to capture two-dimensional (2-D) x-ray images, however may include software intended to process multiple images to create a three-dimensional (3-D) image/model (tomosynthesis).
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →