Class II
Siemens Healthineers · Model MAMMOMAT Inspiration
Full-field digital mammography system with tomosynthesis option and patient-comfort compression paddle design.
Intended use: Low Dose The primary advantage of MAMMOMAT Inspiration is low dose. To match the breast density and body profile of your patients, it offers three anode/filter combinations. Opdose automatically selects the best possible anode/filter combination and the lowest possible dose for the individual breast characteristics. Intelligent Compression Siemens’ intelligent Opcomp function applies compression only as long as the patient’s breast is soft and pliable. For best image quality, it stops at the point of optimal compression. Attractive Design The design of MAMMOMAT Inspiration is one of a kind. Its smooth round shapes and clear lines are emphasized by the soothing cover colors. MAMMOMAT Inspiration’s individual style was assigned with the renowned reddot Award and the IF Award. MoodLight The most significant design element is the unique LED light panel. It provides a comfortable environment and can be easily set according to your personal preference. Information Video for Women With this video, women can see for themselves how easy and uncomplicated getting a screening mammogram with MAMMOMAT Inspiration is.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead lines, failed flat-field calibration, failed ACR / MQSA phantom.
Root cause: Detector degradation, a calibration issue, or a bad pixel map.
Symptoms: Compression will not apply or hold the set force, paddle not recognised, force readout wrong.
Root cause: Compression drive / motor, the force sensor, or a paddle-detect fault.
Symptoms: C-arm will not rotate / lock, angle readout wrong, or the acquisition workstation loses the gantry.
Root cause: Rotation drive / brake / encoder, or the gantry-to-AWS link.
Symptoms: Exposure inhibited, kV / mAs error, tube-overload interlock, AEC fault.
Root cause: Generator, the mammo tube / filters, or the AEC.
Symptoms: Images will not display, mark-up or send to PACS / review workstation.
Root cause: AWS PC or the DICOM configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| Compression drive / force sensor | Major service part | $$$ | Difficult |
| C-arm rotation drive / encoder | Major service part | $$$ | Difficult |
| Mammo X-ray tube / filter assembly | Major service part | $$$$ | Expert-level |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.