Philips Healthcare · Model BrightView XCT
BrightView XCT enables low patient dose levels, high-resolution localization, and high-quality attenuation correction with the potential for fewer artifacts and shorter exam times. BrightView XCT puts patients at the center of care. The patient zone is designed to create an optimum physical and emotional environment for patients. Flexible breathing protocols offer greater patient comfort. An ultra-large gantry aperture provides an open patient experience. Table limit is 500 lbs (227 kg). BrightView XCT features proven BodyGuard automatic contouring to speed set up and ZeroGap planar imaging to allow minimum detector-to-detector distance of 0” (0 cm) for closer positioning. BrightView XCT can acquire the entire heart volume in just one rotation and permits patients to breathe normally during SPECT and CT acquisitions. The system improves registration confidence between emission and transmission maps because the table remains stationary in many cases. Astonish reconstruction technologies can cut acquisition time in half. The new NM Application Suite helps to streamline your workflow, saving you time reviewing and analyzing studies. Now you can add CT without adding real estate. Surprisingly compact and easy to install, BrightView XCT fits into a room as small as 15’ 6” x 12’ (4.72 x 366 M) with minimal shielding and no need to specially reinforce flooring in most cases. BrightView XCT is designed specifically for nuclear medicine and does not require CT retraining for nuclear medicine technicians.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →