Philips Healthcare · Model Azurion 7 F20 and C20
Insightful Live Image Guidance - expand capabilities to perform challenging procedures with confidence Enhance Visibility - your vascular procedures benefit from excellent image quality and a wider anatomical coverage Save Time - team members can work on all activities - at one or more work-spots - without interrupting each other Simplify Set-Up and Operation - the system uses ProcedureCards that can be fully customized to simplify and standardize system set-up for all cases and users Full Control at Table Side - pre-procedural data, multi-modality imaging from PACS and other sources, and interventional applications can be displayed Manage Dose Efficiently - includes ClarityIQ, x-ray imaging technology which provides hight quality imaging for a comprehensive range of clinical procedures.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy, low-contrast or artefacted fluoro / DSA images, poor detail.
Root cause: X-ray tube aging, flat-panel detector degradation, or a collimator / filter fault.
Symptoms: Gantry rotation, angulation or the L-arm / ceiling stand will not move or gives a position error / collision stop.
Root cause: Drive motor, encoder, brake, or a collision-sensor fault.
Symptoms: Table float, tilt, cradle or height will not move or drifts.
Root cause: Table drive / brake, the tabletop float solenoid, or a control fault.
Symptoms: Exposure inhibited, kV / mA error, tube-overload or thermal interlock.
Root cause: Generator fault, tube thermal limit, or the cooling system.
Symptoms: Review workstation or the large in-room monitor blank, no images to PACS, module not communicating.
Root cause: Video routing, a workstation fault, or a network / PACS-interface fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
OEM service; image-quality re-calibration required.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube assembly OEM service; image-quality re-calibration required. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| C-arm / stand drive motor & encoder | Major service part | $$$$ | Expert-level |
| Table drive / float solenoid | Major service part | $$$ | Difficult |
| Tube cooling unit / heat exchanger | Major service part | $$$ | Difficult |
| Review workstation / video-routing hardware | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.