Pelton and Crane · Model Spirit 1800
Arm Slings Standard with 1803 and 1804 models, patient arm slings support the patient while in a supine position while maintaining constant comfort. Toeboard Form-fitted seat foam combined with a wide toeboard means the 1800 chair maintains patient support and comfort during all procedures. Quick-Release Headrest The quick-release, dual articulating headrest enables you to position each patient for optimal access to the oral cavity. A squeeze mechanism allows for fast and easy positioning during any exam. An optional flat headrest with magnetic pillow is also available. Swivel Lock A tension released swivel lock allows for quick patient rotation. Adjust the patient 30° in either direction for positioning flexibility during any procedure.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unresponsive controls, won't power on.
Root cause: PSU or control board aging.
Symptoms: Loose joints, unstable frame.
Root cause: Fastener/bearing wear from repeated use.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Control panel / PCB | Major service part | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Modification of the Pelton & Crane Spirit 3000 unit disabled the TLC SAFEdrive feature rendering it ineffective in detecting whether the handpiece is potentially damaged or heating up.
The Link Arm Assembly that connects some rear mounted options to the Spirit 3000 or Spirit 1800 dental chairs may potentially break and fall off the dental chair.
Magnetic headrests may affect patients with implantable pacemakers and defibrillators.
The Dental Chair lacks a valid Device History Record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →