OHIO MEDICAL, LLC · Model HS-02UO-DMM4C4M
2' HOSE ASMB USA OXY DM*M4 COND 1/4" MRI
Intended use: A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia unit, analgesia unit, and other O2 dependent respiratory device). The gas pressure in the tubing will be low, a "working pressure" (e.g., 3 - 5 bar), having been reduced by a regulator from a high pressure. The tubing is reinforced with, e.g., woven polyester or cotton and intended for use within a static clinical environment (e.g., intensive care). It is available in various lengths; some types may include an integrated mount. This is a reusable device.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →