Nuve · Model OT 4060V
• Temperature range: 110°C / 140°C. • Ideal for the sterilization of materials in very wide range of areas: Operating theatres and laboratories of hospitals; biology, veterinary and agriculture departments of the universities; quality control laboratories of industries such as food. • Double enveloped constructionwith integrated steam generator. • Fully automatic operation with programmable microprocessor control system. • Digital displays for temperature and time. • Two manometers for chamber and steam generator pressure. • Leds for the cycle steps. • Warning leds for open lid, over- pressure and heater failure. • Lid locking system and electrical and mechanical safety systems against over- pressure. • Preset pre-vacuum and programmable post-vacuum functions. • Maintenance - free diaphragm type vacuum pump. • 0.2 µm biological filter at air intake line.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: Poor air removal, non-condensable gas fault.
Root cause: Worn vanes/seals.
Symptoms: Temp out of tolerance, failed Bowie-Dick.
Root cause: Sensor aging.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Most-replaced wear item.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door gasket / seal Most-replaced wear item. | Periodic replacement | $$ | Fairly easy |
| Steam generator heating element | Periodic replacement | $$$ | Difficult |
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.