NuAire · Model PureCell NU-5100
Constant Contamination Control A unique HEPA filtration system filters fresh air into the pump, CO2 gas from tanks or house systems, IR CO2 sensor sample air returning to the change, air between air pump and inner chamber, while continuously filtering the internal chamber to create ISO Class 5 air quality. Cleanroom within a Cleanroom Interior chamber is constantly maintained at positive pressure similar to an ISO Class 5 Cleanroom. Thermal Conductivity Gas Control Thermal Conductivity (TC) CO2 sensor provides reliable monitoring of CO2 levels. Precision of Electronic Microprocessor Controls A programmable microcontroller samples input sensors, sets control outputs, and makes necessary corrections to the chamber environments resulting in quick and responsive recovery times. Reliability and Protection of Automated and Redundant Back-up Systems A temperature sensor probe, solid-state analyzers, HEPA filtration systems, and status alarms create a dependable, long lasting scientific instrument. Critical Cleaning Components Coved corners prevent contaminants from becoming trapped in the chamber. Removable shelves, brackets, and gasket make cleaning simple by cleaning around them or placing them in the autoclave. Homogeneous Temperature All 6 sides of the chambers walls feature heating elements surrounded by R5 insulation to provide optimum temperature uniformity in the work chamber.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Chamber above or below setpoint, temperature alarm, slow recovery after the door opens.
Root cause: Heater element, a temperature-sensor / controller fault, a door / gasket leak, or a circulation-fan fault.
Symptoms: CO2 above or below setpoint, CO2 alarm, pH drift in cultures.
Root cause: CO2 sensor (TC or IR) drift, an empty / low CO2 supply, or a solenoid / regulator fault.
Symptoms: Low humidity, plates drying out, condensation problems.
Root cause: Empty water pan, or an evaporation / airflow issue.
Symptoms: Chamber stops heating, over-temp alarm, will not restart.
Root cause: Controller / sensor fault driving the heater high, or an independent over-temp thermostat.
Symptoms: Door will not seal, temperature swings, condensation at the door.
Root cause: Worn door gasket or a sagging hinge.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Heater element | Major service part | $$ | Moderate |
| Temperature sensor / controller | Major service part | $$ | Moderate |
| CO2 sensor (CO2 incubator) | Periodic replacement | $$$ | Moderate |
| CO2 solenoid / regulator (CO2 incubator) | Major service part | $$ | Moderate |
| Door gasket | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.