NuAire · Model NU-5720
PRECISE HUMIDITY CONTROL Relative humidity levels up to 90% are achieved in the growth chamber through the use of a 3-liter reservoir external to the chamber. The chamber air is routed through the water vapor saturated the air in an evaporate box to add humidity when the RH sensor indicates more humidity is needed to meet set point. DUAL DECONTAMINATION CYCLES The direct heat technology enables the use of a 145°C dry and 95°C humidified decontamination cycle that can be conveniently run overnight in just 8 hours without removing the CO2 or temperature sensors. The NuTouch control system steps the user through the process with on screen instructions and displays progress throughout each phase of the complete cycle.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Chamber out of set-point range, alarm.
Root cause: Heater element or sensor drift.
Symptoms: Gas concentration alarm, contamination risk.
Root cause: Gas sensor or solenoid valve wear.
Symptoms: Humidity drift, condensation.
Root cause: Aged door gasket.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| CO2 sensor | Periodic replacement | $$$ | Moderate |
| Door gasket / seal | Periodic replacement | $ | Fairly easy |
| Temperature sensor | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.