Norav Medical · Model NBP-24 NG
• Complies with the BHS (British Hypertension Society) and ESH requirements • Gentle and fast measurement of blood pressure achieved by Auto Feedback Logic • Patient comfort is achieved by auto feedback Logic at the same time as high measurement accuracy is ensured • Day / Night button allows for exact documentation of sleep and awake phases for statistically accurate evaluation as well as an exact documentation of the early morning blood pressure rise • Extensive diagnostic and profile comparison for optimizing therapy control • Wireless Bluetooth transfer of data or via USB cable • Direct connection to PC • Compact dimensions, weights only 240gr including buttery • Documentation and storage of 24/48 hour ambulatory data • Export data in XML /GDT/BDT formats to a PC or medical file • Compatible with Windows 2000, ME, XP, Vista, Macintosh OS X 10.4 and higher, and Linux
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.