Micrel · Model Rythmic PCEA
A higher pressure limit range. A range of dedicated transport bags for external container infusion Custom made menu with or without Bolus/Dose limit/Loading dose to fit therapy protocols and avoid set up errors. Easy review of patient history thanks to easy-to-read history menu on the pump graphical display or the handy portable printer. Simplified set up menu for 3 steps start procedure: Enter Rate+Volume to infuse and Start infusion. Incorporates “Preventive Maintenance” management The pump has been designed to decrease most of unnecessary potential alarms whilst preserving full safety: No air alarm thanks to the air in line eliminator incorporated in all sets. Automatic restart after occlusion release. Long battery autonomy (7 days at 2ml/h) to decrease the frequency of battery alarms and related changes. Small, ergonomic and compact for true and comfortable ambulatory therapies. Pump size already includes the drug volume (up to 160ml) Outstanding battery autonomy.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Occlusion alarm, no flow, upstream pressure high.
Root cause: Kinked set, clamped line, patient vein issue.
Symptoms: Air-in-line alarm, infusion paused.
Root cause: Air in set, improperly primed tubing.
Symptoms: Uncontrolled flow when door open.
Root cause: Worn roller or failed free-flow valve.
Symptoms: Set not recognized, door-open error.
Root cause: Dirty or failed door microswitch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable; per patient.
Common R&R on high-mileage pumps.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door microswitch | Periodic replacement | $ | Fairly easy |
| Occlusion sensor assembly | Periodic replacement | $$ | Moderate |
| IV administration set Consumable; per patient. | Consumable | $ | Easy |
| Peristaltic roller / pump mechanism Common R&R on high-mileage pumps. | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.