MELAG · Model Vacuklav 24 B/L
MELAG Vacuklav 24 B/L [b]Tap-water connection necessary Chamber depth: 60 cm, 29 litres[/b] The Vacuklav 24 B/L+ is a class "B" autoclave according to the European standard EN 13060 and therefore absolutely fit for the future. It works according to the fractionated pre-vacuum method. This means: At first the air is evacuated from the chamber with a very effective vacuum pump. Then there is a repeated intake of steam which is always immediately pumped out again. The result is that at the beginning of the actual sterilization, there is no longer any air in the chamber or in wrapped hollow instruments or in textiles which would endanger the success of the sterilization. The Vacuklav is equipped with a fractionated post vacuum for effective drying as a prerequisite for long-term storage of wrapped sterilized materials. Sensors and an innovative microprocessor control regulate and monitor the parameters pressure and temperature necessary for a secure sterilization.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: No steam, low temp, cycle abort.
Root cause: Failed heating element or scale buildup.
Symptoms: Temp out of tolerance, failed Bowie-Dick.
Root cause: Sensor aging.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Steam generator heating element | Periodic replacement | $$$ | Difficult |
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
| RO/DI feed cartridge Consumable. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.