Easily upgradeable Software and Hardware Improved syringe design for quick, easy install and detachment Automation Features: Integrated Auto Load, Auto Retract, Auto Prime, Auto Syringe Sensing Remote Check For Air confirmation button on CT injector head Remote Arming at CT injector head Color Touchscreen Pressure Monitor Graph to display real-time pressure during injection Programmable Pressure Limit Integrated Test Inject to ensure patency of vein Graphical, real-time Flow Profile Stopwatch Timer Protocol Lock.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Injector will not advance the plunger, stalls, pressure-limit or motor-fault alarm.
Root cause: Drive-motor / lead-screw wear, a syringe-interface / plunger-ram fault, or a pressure-transducer fault.
Symptoms: Air-detector alarms with no air, or fails to detect air, will not arm.
Root cause: Air-detector sensor or a dirty / damaged sensor window.
Symptoms: The console loses the injector head, hand-controller unresponsive, arm / pause not working.
Root cause: Head-to-console cable / wireless link or a board fault.
Symptoms: Contrast not warmed, warmer alarm.
Root cause: Syringe / bath heater or its sensor.
Symptoms: Short run time, will not hold charge.
Root cause: Aged battery pack.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive motor / lead-screw assembly | Major service part | $$$ | Difficult |
| Plunger ram / syringe-interface assembly | Major service part | $$ | Moderate |
| Pressure transducer | Major service part | $$ | Moderate |
| Air-detector sensor | Major service part | $$ | Moderate |
| Battery pack (mobile heads) | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.
Synced live from the FDA openFDA API.
The root cause investigation showed that the under-volume hazard can occur when the unit has been configured to prime with contrast, but instead primes with saline due to the configuration data not being sent to the injector head. This may create a non-optimal priming condition that could lead to under-infusion.
Packaging may exhibit open seals - sterility compromised
Kits contain a T connector that may be susceptible to cracking or breaking or leaking. This could cause product leakage or, less likely, patient injury.
the heat maintainer, an accessory, may overheat and deform the disposable syringe
Sterility can be compromised by a tear in the outer packaging.
Sterility can be compromised by a component tearing the outer packaging
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.