Medical International Research · Model Spirodoc
Touch screen. Non-invasive. Patient eDiary. On-screen results. Home care symptoms diary. 6-Minute Walk Test. Triaxial Accelerometer. Capable of sleep desaturation study. Respiratory Rehabilitation Monitoring. Activity Monitoring. Long life rechargeable battery. Wireless real time test on PC via Bluetooth. May be used for both home and office use.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: 3 L syringe check outside tolerance, volume / flow drift over the day, biological control out of range.
Root cause: Flow-sensor contamination or wear (pneumotach / turbine / ultrasonic), a leak, or ambient (BTPS) correction not set.
Symptoms: Erratic traces, poor repeatability, back-extrapolated volume errors.
Root cause: Worn or wet flow sensor, a damaged filter seat, or a leak in the tubing / mouthpiece connection.
Symptoms: DLCO or FRC results implausible, gas-analyser calibration fails, drift.
Root cause: CO / CH4 / He / tracer analyser drift or an analyser fault, or a demand-valve / gas-supply issue.
Symptoms: Box pressure will not stabilise, thermal drift, door-seal leak.
Root cause: Door seal, the box pressure transducer, or thermal equilibration.
Symptoms: Test hangs, results will not save, print or export.
Root cause: Workstation PC, software, or the printer.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Calibrate / verify the syringe periodically.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flow sensor (pneumotach / turbine / ultrasonic) | Periodic replacement | $$ | Fairly easy |
| Calibration syringe (3 L) Calibrate / verify the syringe periodically. | Major service part | $$ | Easy |
| Gas analyser cell (DLCO / lung-volume systems) | Periodic replacement | $$$ | Moderate |
| Plethysmograph door seal / pressure transducer | Periodic replacement | $$ | Moderate |
| Sample lines / demand valve | Frequent wear item | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.