LTE Scientific · Model R/PL Series
• Cylindrical Chamber - Made from 316L grade stainless steel. Fully compliant with the European pressure equipment directive 97/23/EC. Independently certified to PD5500:2000 Cat. 3. The chamber if fully insulated. • Touchscreen Control System - This system is the standard operating platform across the whole LTE autoclave range. It incorporates a state-of-the-art touch-sensitive screen. Using a series of on-screen prompts and icons, the system is both versatile and simple to use. See below for further details. • Integral Steam Generator - A high performance stainless steel steam generator is fitted under the chamber which delivers steam quickly and effectively to the chamber and load, minimizing re-heat times between negative pulsing and speeding up cycle times. • Vacuum System - Our vacuum system incorporates an efficient liquid ring pump capable of delivering vacuum levels below 50mbarA, ensuring effective air removal and fast drying. • Steam Jacket - Drying of the load is achieved by means of combination of vacuum and heat. A fully insulated copper coil steam jacket is provided as standard which effectively heats the chamber and load during the vacuum drying stage, dissipating any remaining moisture and ensuring a dry load at the end of the cycle.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: No steam, low temp, cycle abort.
Root cause: Failed heating element or scale buildup.
Symptoms: Poor air removal, non-condensable gas fault.
Root cause: Worn vanes/seals.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
Most-replaced wear item.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
| RO/DI feed cartridge Consumable. | Frequent wear item | $ | Easy |
| Door gasket / seal Most-replaced wear item. | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.