LIARRE · Model Neptune and Neptune Print
• Medical device (Directive 93/42/CEE) class IIa • Capacity 15 litres. • Chamber depth of 35,6 cm • All functions are microprocessor controlled. • The closing and locking of the door is completely automatic • Easy to use thanks to the large graphic display and symbols. • Built-in printer. • The autoclave can be connected to the mains water system through a water demineraliser (accessory available separately). • 10 cycles for wrapped and unwrapped instruments • 2 test cycles • Automatic drying • Model with built in printer and capacity 23 lt. • Chamber depth of 51,5 cm • Model without the printer, with connection RS232
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: Poor air removal, non-condensable gas fault.
Root cause: Worn vanes/seals.
Symptoms: Temp out of tolerance, failed Bowie-Dick.
Root cause: Sensor aging.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Most-replaced wear item.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door gasket / seal Most-replaced wear item. | Periodic replacement | $$ | Fairly easy |
| Steam generator heating element | Periodic replacement | $$$ | Difficult |
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.