Kodak · Model 4000mm Pro
Generate powerful molecular imaging results with the high-performance, versatile Kodak Image Station 4000 MM PRO. The Kodak Image Station provides high- sensitivity multimodal optical molecular imaging for in vitro samples, with options for adding in vivo imaging capabilities. The system provides high-quality results using state-of-the-art cooled CCD technology and a 10x optical zoom lens for imaging fluorescence, chemiluminescent, chromogenic, and optional radioisotopic labels in gels, blots, plates, and more. This system offers multi-wavelength illumination from 385-770 nm for excitation of a wide range of fluorochromes, and the proprietary wide angle filters provide emission from 440-830 nm generating images of unmatched quality.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.