Karl Storz · Model Endomat Select
User-friendly interface and simple handling thanks to tubing set for single hand control Rapid communication with the shaver unit Safe use thanks to tubing set recognition Seamless integration into existing systems Optional software allows further applications to be added at any time License, allows selection of the procedures "knee," "hip,' "shoulder" and "small joints," for use the ENDOMAT®SELECT UP 210 Tubing Set- irrigation, PC, for single use, sterile, package of 10, for use with KARL STORZ HAMOU® ENDOMAT®263311 20 and ENDOMAT®SELECT UP 210 for transmission of the footswitch signal between UNIDRIVE® S III ARTHRO SCB 28 723020-1 and ENDOMAT®SELECT UP 210
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.