Instrumentarium · Model Dental Express Origo
Comfortable imaging plates – Flexible and comfortable imaging plates provide an easy-to-learn workflow with no cables Just insert the plate. No chemicals needed. Plates immediately ready for re-use. The entire process from reading the image to erase the re-usable imaging plates for the next use takes only a few seconds.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Fogged, streaked, mottled or under-developed films; density drift on the sensitometric strip.
Root cause: Exhausted or wrongly mixed chemistry, wrong developer temperature, or dirty / worn rollers.
Symptoms: Film jams between racks, does not advance, or comes out crumpled.
Root cause: Worn or misaligned transport rollers / racks, worn drive gears, or a crossover-rack fault.
Symptoms: Developer not at set temperature, density varies through the day.
Root cause: Heater, thermostat / sensor, or recirculation-pump fault.
Symptoms: Chemistry not replenished, developer / fixer levels drift, films degrade over a batch.
Root cause: Worn replenishment-pump tubing or a pump fault.
Symptoms: Films come out damp.
Root cause: Dryer heater or blower fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Transport / crossover rollers & gears | Periodic replacement | $$ | Moderate |
| Replenishment-pump tubing | Frequent wear item | $ | Fairly easy |
| Developer heater / thermostat | Major service part | $$ | Moderate |
| Recirculation / replenishment pump | Periodic replacement | $$ | Moderate |
| Dryer heater / blower | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Instrumentarium Dental has delivered a number of FOCUS 3.0 Intraoral X-ray units in November 2013 with a potential flaw in the mounting hardware. A number of wall mount units were delivered with FOCUS X-ray machines that had not been properly welded at our supplier. As a result of the incomplete welding operation, the wall mount unit on the FOCUS X-ray unit may not properly support the unit as expected, which could cause the unit to drift. Depending on the extent of the shortened or missing welds, there is also a possibility that the wall mount unit will fail to support the weight of the unit, resulting in the FOCUS X-ray unit falling unexpectedly from its mounted position.