AGFA · Model Mamoray Classic E.O.S.
For reliable mammography optimized processing with reduced chemical costs, look no further than the MAMORAY Classic E.O.S. processor. Agfas Ecologically Optimized System With Agfa's unique "Ecologically Optimized System" approach, the MAMORAY Classic E.O.S. processor allows you to comply with ecological standards while reducing fixer consumption, silver content in the wash water and water consumption. The silver content in the washing water is reduced to 1 ppm at regular water consumption rates, and to 50 mg/m² at reduced water consumption rates. Excellent image quality The racks in the MAMORAY Classic E.O.S. processor have been specially designed for dedicated mammographic processing or for mixed processing of general radiographic and mammographic images. The result is image quality that meets the most stringent regulations imposed by different countries. The MAMORAY Classic E.O.S. processor offers you a choice of processing cycles: RP (Rapid Processing) and EXT (Extended Cycle), providing you with optimum image quality of your films. IP (Intermediate Processing) will be added to new E.O.S. universal software. Photographic consistency The developer temperature can be selected and monitored through a control panel. The developer temperature will be controlled within a tolerance rate of ±0.3 °C. Room to insert a thermometer to calibrate and monitor the photochemical process has been foreseen. The automatic jog cycle will replenish the chemicals at regular intervals to ensure optimum processing conditions. All these features contribute to consistent image quality, facilitating daily quality control. User-friendliness The MAMORAY Classic E.O.S. processor's functions are microprocessor-controlled. Its user-friendly control panel has an interactive 2 x 16 digit LCD display (12 languages). The MAMORAY Classic E.O.S. processor offers you the very best in processing technology. Its infrared drying modules provide superior drying performance and generate low heat so as not to disturb the working environment. Easy installation A single phase, 15/16 A wall outlet and standard plumbing connections are all you need to install the MAMORAY Classic E.O.S. processor properly.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Films too light / dark, low contrast, chemical fog, streaks or drag marks.
Root cause: Exhausted or wrongly mixed developer / fixer, wrong replenishment rate, or a temperature-control fault.
Symptoms: Film jams between racks, crossovers or the dryer, transport stalls.
Root cause: Worn or dirty transport rollers / gears, or a chain / drive fault.
Symptoms: Developer temperature drifts, density varies day to day.
Root cause: Heater, temperature sensor, or the circulation pump.
Symptoms: Chemistry not topped up, tanks over/underfilling, pump not running.
Root cause: Replenishment pump or float / level sensor.
Symptoms: Films come out damp, dryer not heating or the blower not running.
Root cause: Dryer heater or blower.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Transport roller / crossover racks | Periodic replacement | $$ | Moderate |
| Developer / fixer chemistry | Consumable | $$ | Easy |
| Heater / temperature sensor | Major service part | $$ | Moderate |
| Replenishment pump | Periodic replacement | $$ | Moderate |
| Dryer heater / blower | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
The film was incorrectly notched.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio