Impact Instrumentation · Model UniVent 754
Deliverable Gas(es) Air (Internal Compressor, External 50-PSI); Oxygen (External 50-PSI) Tidal Volume Range 0 to 3000 mL I:E Ratio 1:1 Preset, Adjustable 1:1 to 1:599 Sensitivity Default, 1.5 to 2.0 cmH2O; Adjustable, 1.0 to 6.0 cmH2O Flow Rate Adjustable, 0 to approximately 60 LPM (0 to approximately 1000 ml/sec) Ventilation Rate Adjustable, 1 to 150 bpm, in 1bpm increments (±1 digit on the display panel) Inspiration Time Adjustable, 0.1 to 3 sec, in 0.1 sec increments (±1 digit on the display panel); 1:2 I:E RATION preset FiO2 Adjustable, 21% to 100% (Internal Air/Oxygen Mixer), resolution in 1% increments, accurate to within ±10% Low Pressure Alarm Adjustable, 0 to 50 cmH2O, in 1 cmH2O increments (±1 digit on the display panel) High Pressure Alarm Adjustable, 15 to 100 cmH2O, in 1 cmH2O increments (±1 digit on the display panel)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Inaccurate delivered volume, false volume/pressure alarms.
Root cause: Sensor contamination or aging of differential-pressure transducer.
Symptoms: Unable to reach set pressure, low-flow alarm, loud noise.
Root cause: Worn bearings or failed blower motor.
Symptoms: Unexpected shutdown, persistent low-battery alarm.
Root cause: Aged internal battery or failed PSU.
Symptoms: Leak alarm, low circuit pressure, volume loss.
Root cause: Disconnected or punctured patient circuit / humidifier.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Most-replaced wearable part; stock spares.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| O2 sensor (galvanic/paramagnetic) | Frequent wear item | $$ | Fairly easy |
| Exhalation valve assembly Most-replaced wearable part; stock spares. | Frequent wear item | $$ | Fairly easy |
| Flow / differential pressure sensor | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Ten units of Model EMV+ Devices were shipped out in error before the verification and validation was completed for a new integrated circuit (IC) on the CPU PCB.
Model 754/754 M Disposable MRI Ventilator Circuits are being distributed without market clearence (510k).