I. C. Medical · Model 350D
A patented sensor system turns the evacuator on and off when the surgeon activates the electrosurgical laser, argon beam coagulator, or other smoke producing instrument. The Crystal Visions are very easy to live with in the operating room. They are small, weigh about seventeen pounds, and are very quiet. Most O.R staffs simply slip the Crystal Vision onto a shelf on the electrocautery cart. The 350-D automatically stops the vacuum pump if tissue is trapped in the evacuation tube. The evacuators automatically restart when the tissue, or other obstruction is cleared from the tube. Both models automatically tell the operator when to replace the input filter. This reduces procedural costs, eliminates guessing, and provides for the best removal of smoke from the surgical site. The model 350-D is further separated from other smoke evacuators when it is used during laparoscopic procedures for removing smoke. The 350-D was designed specifically for these procedures and this system has several features unique to any smoke evacuation system. A pneumoperitoneum is created during laparoscopy by inflating the abdominal cavity with carbon dioxide gas from an insufflator. The inflation allows the surgeon to see better and creates a much safer operating environment for the patient. Leaks in the instruments and suctioning of fluids (and gas) decreases the carbon dioxide in the abdomen. The insufflator senses the lower pressure and adds more gas. Surgeons frequently rest their arm or actually lean on the patient. This can cause the pressure in the pneumoperitoneum to increase above safe levels but the insufflators cannot reduce the pressure because they are only designed to add gas to the abdomen.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Smoke lingers in the field, weak suction at the pencil / wand, capture alarm.
Root cause: Saturated ULPA / charcoal filter, a kinked or blocked hose, or a worn blower.
Symptoms: Filter-change warning, reduced airflow.
Root cause: Filter at end of life or not fully seated.
Symptoms: Rising noise, vibration, airflow falling off over time.
Root cause: Worn blower / turbine bearing.
Symptoms: Evacuator does not start with the ESU or footswitch.
Root cause: Activation sensor or footswitch fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| ULPA + charcoal filter Consumable. | Frequent wear item | $$ | Easy |
| Blower / turbine unit | Major service part | $$$ | Difficult |
| Suction tubing / wand | Frequent wear item | $ | Easy |
| Footswitch / activation sensor | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.