Hologic · Model Panther Fusion
Up to 32 assay reagent kits on board, which allow assay consolidation on a single platform Ready-to-use reagent cartridges reduce manual preparation and operator errors Sample throughput up to 500 tests in 8 hours increases test volume in a shift without increasing staff Minimal hardware/software changes allow additional testing without extensive retraining or SOP updates.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Carriers / pucks jam, stall, or mis-route; track-error message; throughput drops.
Root cause: Worn track belts / drive, a diverter / gate fault, or a carrier-sensor fault.
Symptoms: Tubes dropped or mis-placed, gripper-position error, aliquotting mis-aligned.
Root cause: Worn gripper / robot drive or an encoder / home-sensor fault.
Symptoms: Inline centrifuge imbalance, lid-lock error, will not spin.
Root cause: Drive / bearing wear, a lid-lock fault, or an imbalance-sensor fault.
Symptoms: Caps not removed / applied, aliquot volumes off, station jams.
Root cause: Worn decapper jaws, aliquot-probe / syringe wear, or a station-drive fault.
Symptoms: Analysers or the LIS drop off the line, rules not applying, samples stuck in a queue.
Root cause: The automation middleware / server or a network link.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Track belts / drive components | Periodic replacement | $$$ | Difficult |
| Robotic gripper / drive assembly | Periodic replacement | $$$ | Difficult |
| Centrifuge-module drive / lid-lock | Periodic replacement | $$$ | Difficult |
| Decapper jaws / aliquot-probe & syringe | Periodic replacement | $$ | Moderate |
| Carrier / position sensors | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.