Five individual low-pressure zones, including a dedicated heel zone. Real-time pressure adjustment controlled by the internal I-mmersion sensor adjusts internal cushion pressures instantly according to patient size, shape, weight or position. Flexibility in choosing between continuous or alternating low-pressure therapy modes. Continuous Micro-climate Management limits the effects of temperature and moisture build-up. Dedicated heel zone with ultra-low pressure for optimal protection of the vulnerable heel area, and with enhanced lower-leg support. One touch P-MAX feature provides fast inflation to for easier patient re-positioning and transfer. Patient Egress Alarm informs nursing staff of any undesired patient egress from the bed.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Patient bottoms out, low-pressure alarm, surface stays soft.
Root cause: Blower/pump fault, a hose disconnect or kink, or a bladder / air-cell leak.
Symptoms: Localised loss of support.
Root cause: Perforated air cell or a failed cell connector.
Symptoms: Patient feels damp, little airflow through the coverlet.
Root cause: Clogged air filter or low blower output.
Symptoms: Tears or cracking in the top cover, fluid ingress.
Root cause: Wear or sharp objects - do not use with a compromised cover.
Symptoms: Surface does not deflate quickly on the CPR control.
Root cause: CPR dump valve or hose fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Pump / blower unit | Periodic replacement | $$$ | Moderate |
| Air cell / bladder | Periodic replacement | $$ | Fairly easy |
| Hose and connectors | Periodic replacement | $ | Fairly easy |
| Air filter | Frequent wear item | $ | Easy |
| Mattress top cover | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.