Hettich · Model ROTANTA 46 RSC ROBOTIC
• Up to 89 complete running programmes can be memorized and recalled by their storing number • Efficient cooling: Temperatur is steplessly controllable within a range of -20 °C to +40 °C • Speed: n=4,500 min-1 with a 4-place swing-out rotor that (depending on th suspensions) corresponds to a max. RCF 4.754 • High capacity: 4 x 250 ml or 4 x 750 ml or 16 x MTP, 4 x DWP or comparable systems • Frequency-controlled drive • Housing and lid of metal • Panelling finished in scratch and impact resistant coating • Centrifuging chamber of stainless steel • Double indication when the rotor is stationary • Imbalance switch-off • Hatch locking • Motor and chamber overheating protection • Emergency lid lock release • Excess temperature protection of the brake resistors • Additional control of the information transfer
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →