H&abyz Co., Ltd · Model A1717MCW
The A1717MCW/A1417MCW/F1417MCW is a Flat Panel Digital X-ray Detector which have 425.04 x 425.6mm (A1717MCW) or 345.24 x 425.6mm (A1417MCW/F1417MCW) effective pixel area. The device communicates by the wired Ethernet and wireless Wi-Fi communication feature. The detector should be integrated with a Console PC and an X-ray generator to utilize as digitalizing X-ray images and transfer for radiography diagnostic (the Console PC and X-Ray Generator are not provided from H&abyz). The A1717MCW/A1417MCW/F1417MCW consists of the following components: Flat Panel Detector, power supply box, cable, batt.
Intended use: An electrically-powered, cassette-like device intended to be used as part of an x-ray system to detect x-ray images following exposure, and create a digital signal; it is not dedicated to imaging of a specific anatomy. It includes two types of transducing technology (i.e., indirect): a scintillator [e.g. caesium iodide (CsI)] screen converts x-ray energy into light, followed by the conversion of light into a digital signal by photodiode array. The image data can be sent to an appropriate processing unit through a wired or wireless connection (e.g., Wi-Fi). It may be used in place of a fixed detector in x-ray imaging systems, e.g., as part of a digital imaging conversion system.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The medical imaging is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.