GE HealthCare · Model SMV DST-XLi
INCOMPARABLE OPEN GANTRY The DST-XLi combines variable angle geometry, pioneered by SMV, with an open gantry design so ingenious it’s patented. Patients can be easily imaged on hospital beds, stretchers, or sitting upright. Prone and supine cardiac SPECT is also accommodated. The open design, advanced robotics, and ScintibedTM table work in concert to provide complete multi-purpose versatility. INNOVATIVE LONG-AXIS SPECT The detector orientation of the DST-XLi is optimized in both whole body and SPECT imaging. For whole body,the long axis of the FOV is across the body while for SPECT, it is parallel to the patient’s torso. This exclusive long-axis SPECT orientation optimizes anatomical coverage for oncologic exams, routinely enabling imaging from the C-spine to the sacrum in a single SPECT acquisition. INTELLIGENT DIGITAL DETECTION At the heart of the DST-XLi is SMV’s Digital Deconvolution Detection (D3TM), an innovative approach in digital detector technology to meet the new requirements in nuclear imaging: high count rate for coincidence imaging, uniform performance across the entire field of view, and stable, reliable operation.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
GE Healthcare has recently became aware of a cable failure associated with the arm or gantry rotation of the DST-XL Camera that may impact patient safety.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →