GE HealthCare · Model Senographe 800T
High Frequency X-Ray Generator Delivering Constant Voltage. Gabbay X-Ray Tube Incorporates Several GE Healthcare Exclusive Technological Advantages to Improve Tube Life and Image Quality. Exposure Modes - Three Exposure Modes Offer the Ultimate Flexibility and Ease of Use. Microprocessor Control Guarnantees Exceptional Exposure Reproductibility. Photocell (AOP and AEC) may be Set in Five Different Positions With Respect to Breast Anatomy. Adjustable Film Blackening (11 Steps). Five Film/Screen Combinations. Magnification - Superb Magnification Images are Achieved with 1.5 and 1.8 Magnification Factors and a Single Magnification Platform. Positioning Column. Digital Display of Arm Rotation, Compression Force and Breast Thickness. Motorized Compression is Controlled by Two Compression/Decompression Foot Pedals. Manual Fine Tuning Adjustment. Compression Paddles - Slide Mount for Perfect Stability and Easy Mounting. Image Receptor. Diaphragms - Includes a Set of Blades, Each Dedicated to an X-Ray Beam Format and to the Image Receptor Format. Control Console. DataFlash Patient Identification System Prints Institutional, Patient and Exam Data Directly Onto the Film Following Each Image Exposure.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead lines, failed flat-field calibration, failed ACR / MQSA phantom.
Root cause: Detector degradation, a calibration issue, or a bad pixel map.
Symptoms: Compression will not apply or hold the set force, paddle not recognised, force readout wrong.
Root cause: Compression drive / motor, the force sensor, or a paddle-detect fault.
Symptoms: C-arm will not rotate / lock, angle readout wrong, or the acquisition workstation loses the gantry.
Root cause: Rotation drive / brake / encoder, or the gantry-to-AWS link.
Symptoms: Exposure inhibited, kV / mAs error, tube-overload interlock, AEC fault.
Root cause: Generator, the mammo tube / filters, or the AEC.
Symptoms: Images will not display, mark-up or send to PACS / review workstation.
Root cause: AWS PC or the DICOM configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| Compression drive / force sensor | Major service part | $$$ | Difficult |
| C-arm rotation drive / encoder | Major service part | $$$ | Difficult |
| Mammo X-ray tube / filter assembly | Major service part | $$$$ | Expert-level |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.