GE HealthCare · Model Performa
High image quality…High patient comfort • Easy Compression System: GE exclusivity- Increase the posterior tissue to be imaged up to 8-15mm and reduce the exposure time for better patient comfort. • AEC -GE’s Exclusivity : The correct placement under the densest area of your patient breast is possible with the Automatic Exposure Control system which offers not less than 8 different positions. • Obtain sharper images increasing your grid ratio to avoid scattered radiation with the unique GE Roc grid. • Enhance patient comfort with a wheel chair access thanks to the motorized vertical operation up to 80 cm. A Compact and Ergonomic Solution • When space is a premium, Perfoma is the solution: It only requires a 2,40m (L) × 2,70m(W) room thanks to its integrated generator and very short gantry. • The extremely light and counter-balanced C-arm easily rotates up to 360°C in less than 2 seconds with a simple push of the technologist. • Intuitive remote control panel. • Buttons on C’Arm handles to ease positioning. Performa…for all Women…for all Applications • A screening solution: Women with all type of breast can be examined with a large range of bucky sizes (18x24 / 24x30). • A diagnostic solution: To go deeper in your diagnosis Performa offers some magnification options and spot paddles. • An Interventional solution: The add-on Biopsy system is extremely compact and ease of use with a motorized needle guide.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →