GE HealthCare · Model Millennium MC Myosight
• Designed for high-volume cardiac and many routine general purpose Nuclear Medicine procedures • Rectangular 360mm x 510mm FOV • Highly versatile gantry design – Performs all cardiac procedures including - 180° & 360° in either 101° or 180° orientation, supine & prone, SPECT & Planar, Gated Blood Pool, Dynamic First Pass • Fast and safe semi-automatic simultaneous collimator exchange • Compact table for improved patient handling and comfort • GenieAcq acquisition station includes DICOM and other productivity tools
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
In certain cases, one of the four collimator locking mechanisms that attach the collimator to the head may work itself free if collimator exchange has not been performed for an extended period of time. This situation, if neglected, could eventually cause the locking mechanism to unlock itself.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →