GE HealthCare · Model Discovery NM/CT 670
The power of Discovery State-of-the-art Nuclear Medicine Slim Detectors for general purpose nuclear imaging. Flexibility to combine any supported SPECT and CT single or multiple exams to create hybrid protocols. The technologist saves time by completing multiple examinations in one patient visit. Inherent registration of multiple CT and SPECT FOVs, which permits scanning only the areas that need scanning, thereby reducing both dose and imaging time. Telescopic table design increases hybrid scanning range while ensuring accurate registration throughout the FOV. Responsible dose management for both NM and CT imaging. Next generation multimodality visualization tools on the Xeleris workstation for SPECT/PET/CT/MR. BrightSpeed Elite 16 slice CT with a 0.5 second scan speed. Advanced gantry robotics enabling simultaneous motions on multiple axis, swift setup and faster overall imaging time. A multitude of features designed to improve patient comfort, reduce anxiety and deliver heightened patient experience.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.