GE HealthCare · Model Alpha ST
When image quality meets patient care • The Total Exposure Control (TEC) system and the perfect Phototimer set for you all the parameters to obtain the best contrast on both dense and fatty breast. It prevents dangerous exposure and misleading set-ups to allow you to concentrate on your patient. • The unique 8 positions of AEC ease positioning highlighting the densest area of the breast. A User Friendly Mammography System • With only 40Kg the counterbalanced C-arm of the Alpha ST easily rotates up to 360°C in less than 2 seconds with a simple push of the technologist. • The integrated generator and small control panel makes the Alpha ST the smallest system of the industry. It only requires a room as little as 2, 40 x 2,60 m. • The breast compression is motorized with the possibility of manual fine tuning, allowing the ideal level of compression for each patient. One system for all applications • Screening exams: whatever the breast size is with a wide range of bucky sizes (18x24/ 24x30). • Diagnostic exams: with the breast paddles for spot and magnification exams. • Interventional exams: with Alpha Stereo 4, a unique add-on biopsy system , light and compact designed for the best patient comfort.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →