LC+ Floor Mounted Three-Axis Positioner Design Provides Maximum Positioning Flexibility and Excellent Patient Access in All Views. With Three Motor Driven Axes, the Innovative Advantx LC+ Positioner Makes it Easy to Achieve Even the Most Complex Angulations. Advantx 100 kW Three-Phase Power Unit. 22cm (9in.), 17cm (6.7 in.), 11cm (4.5 in.) Fields of View Allows the Operator to Match the Field Size to the Relevant Anatomy. MX-150 Water Cooled X-Ray Tube with 1.0, 0.5, and 0.3b Effective Focal Spots and Pulsed Fluoroscopy Provides Excellent Cardiovascular Imaging Capabilities. The Tube's 1.95 MHU Heat Capacity Along with a High Heat Dissipation Rate Minimizes the Need for Heat-cooling Delays, Even with Aggressive Techniques. Omega IV Table with 4-Way Mechanical Float and Motorized Longitudinal 2-Way Travel Allows Easy Patient Positioning. Table Side System Control Mounted to the Table Side to Provide Fingertip Access to Common Imaging Functions. Vascular SRI Collimator Combines Both Rectangular and Circular Collimators as well as Optional Contour Filters. Autopositioner Increases Productivity Through Easy Table Side Storage and Access of Commonly Used Positions. This Option Allows Nine Different Operators to Store Eight Unique Positions for a Total of Seventy-Two Stored Positions. DLX - Cardiac Digital System is a Fully Integrated Imaging Subsystem that Meets Key Cardiovascular Imaging Demands Through Extensive Storage and Advanced Post Processing, Display and Quantitative Analysis Capabilities. The DLX-C Digital System Utilizes a UNIX Architecture and Windows-like Environment Ensuring Upgradeability and Ease of Use. The DLX-C is Capable of True Multitasking Allowing Background DICOM Transfer to Archive Devices. DLX High Speed Combo Gateway Provides Both Cardiac DICOM ATM (150 Mbps) Output and Angio DICOM Fast Ethernet (100 Mbps) Output for Acquisitions From the DLX Digital System. Two Monitors on and Ceiling Mounted Overhead Suspension/Boom.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy or dim fluoro, dose creep, poor DSA, ABC not tracking.
Root cause: Flat-panel detector degradation or the dose / image-processing chain.
Symptoms: Fluoro or cine inhibited, generator error code, tube-arc faults.
Root cause: HV generator, the X-ray tube, or the filament supply.
Symptoms: Gantry will not angulate, rotate or reach a stored position; collision trips.
Root cause: Positioner drive, encoder, brake, or collision sensors.
Symptoms: Table float, tilt, height or cradle will not respond; tableside module dead.
Root cause: Table drive, the tableside control module, or its cable.
Symptoms: Pressures / ECG missing on the hemo system, injector arm / interface fault.
Root cause: Hemo transducer inputs, the recording PC, or the injector interface.
Symptoms: Fluoro / cine inhibited after a run, tube-heat alarm.
Root cause: Tube heat limit or a heat-exchanger fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Expert-level |
| X-ray tube assembly | Periodic replacement | $$$$ | Expert-level |
| HV generator components | Major service part | $$$$ | Expert-level |
| Positioner drive / encoder / brake | Major service part | $$$ | Difficult |
| Table drive / tableside control module | Major service part | $$$ | Difficult |
| Heat exchanger / cooling components | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.