Fluke Biomedical · Model UW 5 Ultrasound Wattmeter
• Versatile usage with total pulsed or continuous-average-energy ultrasound sound devices • Calibration verification and auto-zero features to ensure reliable readings • Transducer clamp and centering rings for stable readings • Leveling mechanism for maximum accuracy • Easy documentation with RS232 data transfer • Battery-operated or line-powered for convenient operation • Easy-to-read 3-digit display • Compact and easy-to-use
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Readings out of tolerance on verification check.
Root cause: Reference component aging.
Symptoms: Won't power on, unexpected shutdown mid-test.
Root cause: Aged internal battery or PSU.
Symptoms: Intermittent or no reading through a specific lead.
Root cause: Repeated connect/disconnect cycles.
Symptoms: Blank, frozen, or garbled display.
Root cause: Display module or driver board aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep spares.
Send out for annual re-certification.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test lead set High-turnover; keep spares. | Periodic replacement | $$ | Easy |
| Display module | Major service part | $$$ | Difficult |
| Calibration reference module Send out for annual re-certification. | Major service part | $$$$ | Difficult |
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →