Abbott · Model Alere Afinion AS100 Analyzer
MULTIPLE ANALYTES ON ONE INSTRUMENT The Alere Afinion™ AS100 Analyzer makes it fast and easy to test quantitative determinations of HbA1c and ACR. MULTIPLE SAMPLE TYPES The Alere Afinion™ AS100 Analyzer is designed to enable simple and fast on-the-spot testing, regardless of the sample type, which may be whole blood, plasma or urine, and to deliver accurate results during patient consultation for improved patient management. CONNECTED The Alere Afinion™ Data Connectivity Converter (ADCC) is also included for simple transfer of patient and controls results from the Alere Afinion™ AS100 Analyzer to your LIS/HIS system of choice, including the Alere RALS® system. ALL-IN-ONE TEST CARTRIDGE The Analyzer and test cartridges have been precision engineered with each test cartridge containing an integrated sample collection device and all necessary reagents for a single test. AUTOMATIC SELF-CHECK SYSTEM The Alere Afinion™ AS100 Analyzer eliminates erroneous results with integrated error detection and self-check systems. NO ADDITIONAL CALIBRATION NECESSARY Each lot of test cartridges includes calibration data stored in the barcode label. The calibration data is read by the integrated camera and used for calculating results.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings disagree with a reference standard, verification check outside tolerance.
Root cause: Normal drift - the instrument needs its scheduled factory / accredited calibration (at least every 12 months).
Symptoms: Dead unit, short battery life, will not charge.
Root cause: Depleted or aged battery, or a power / charger fault.
Symptoms: Open or intermittent readings, connection errors, a specific function fails.
Root cause: Worn or broken test leads, mains adapters, patient-lead adapters, or a sensor cable.
Symptoms: One parameter (leakage, insulation, ECG / SpO2 / IBP simulation, defib / pacer energy, ventilator flow / pressure, light / dose) errors or is out of range while others work.
Root cause: An internal source / measurement circuit fault on that channel.
Symptoms: The automation / logging software will not connect.
Root cause: USB cable / port or driver.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
At least every 12 months per the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test-lead / adapter set | Periodic replacement | $$ | Easy |
| Battery | Periodic replacement | $$ | Easy |
| Calibration (factory / accredited) At least every 12 months per the manufacturer. | Frequent wear item | $$ | Easy |
| Communication cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.