Fluke Biomedical · Model ProSim 8
All-in-one patient simulator 80 % smaller and 17 lbs/7.7 kilos lighter than single function simulator test tools. 8-in-1 multifunction patient simulator is a combination ECG simulator, fetal simulator, arrhythmia simulator, respiration simulator, temperature simulator, IBP simulator, cardiac output simulator, cardiac catheterization simulator, NIBP simulator, SpO2 tester, and is the premier SpO2 simulator to test Rainbow multi-wavelength waveforms. Stay-connected ECG posts for easy/secure ECG snap and lead connections. Custom SpO2 r-curve for accurate testing of the latest and future oximetry technologies. Static pressure linearity testing. Repeatable NIBP simulation for dynamic pressure repeatability testing. Physiologically synchronized pulses across all parameters. Barcode scanning and direct data capture and printing functionality. Onboard, customizable patient pre-sets and autosequences for fast/easy testing. Multi-language user interface offers choice of language selection. Integrated, easily-replaceable long-life battery. Wireless communication for remote PC control of test device, as well as data transfer and automated regulatory reporting.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings disagree with a reference standard, verification check outside tolerance.
Root cause: Normal drift - the instrument needs its annual factory / accredited calibration (recommended at least every 12 months).
Symptoms: Dead unit, short battery life, will not charge.
Root cause: Depleted or aged battery, or a power / charger fault.
Symptoms: Open or intermittent readings, connection errors, a specific function fails.
Root cause: Worn or broken test leads, mains adapters, or a shorting-plug / patient-lead adapter.
Symptoms: One parameter (e.g. leakage, insulation, flow, pressure, ECG / SpO2 / IBP simulation) errors or is out of range while others work.
Root cause: An internal source / measurement circuit fault on that channel.
Symptoms: The automation / logging software will not connect.
Root cause: USB cable / port or driver.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
At least every 12 months per the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test-lead / adapter set | Periodic replacement | $$ | Easy |
| Battery | Periodic replacement | $$ | Easy |
| Calibration (factory / accredited) At least every 12 months per the manufacturer. | Frequent wear item | $$ | Easy |
| Communication cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.