Eryigit · Model STR Series
Stand By Feature Cut off feature when water, electricity interruption and saturated steam quality drops There are 2 PT100 in the cell and 1 in the generator; Ability to make precise pressure measurements with electronic pressure transducers Not affected by ± 10% utility voltage changes Unlimited programmable free program feature Has a hepa filter that filters 99.99% of the particles bigger than 0.3 microns Ability to work with steam from the central steam system in hospitals Ability to operate the system until service intervention in case of failure of any of the resistances There are 3 mechanical safety valves for safety purposes It also has the ability to electronically control pressure and temperature with PLC. The validation services for our products are carried out by German accredited organization Hygcen GmbH.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: Poor air removal, non-condensable gas fault.
Root cause: Worn vanes/seals.
Symptoms: Temp out of tolerance, failed Bowie-Dick.
Root cause: Sensor aging.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Most-replaced wear item.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door gasket / seal Most-replaced wear item. | Periodic replacement | $$ | Fairly easy |
| Steam generator heating element | Periodic replacement | $$$ | Difficult |
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.