Embla · Model SD32+™
• Featuring built-in Nellcor oximetry for simplified calibration and tracking of true SpO2 and pulse rate values • Convenient LCD screen to display the impedance check, signal quality check, numeric digital values or montage setup at the patient’s bedside • Plug-and-play interface with GoodKnight™ 425ST Bi-Level™ device via Sandman elink™ adapter • Slim, lightweight headbox with quick disconnect for easy patient mobility • Fully programmable references, filters, gains and sampling rates from within Sandman Elite software • Multireferencing and re-referencing of any channel during collection from within Sandman Elite software • Flexibility for your entire sleep or neurodiagnostic recording needs
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Noisy / flat channels, impedance alarm.
Root cause: Dry gel, poor contact.
Symptoms: Dead channel, artifact.
Root cause: Front-end amplifier failure.
Symptoms: No stimulus delivered.
Root cause: Stimulator circuit wear.
Symptoms: 50/60 Hz interference.
Root cause: Shield/ground break.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| EEG electrode cap / cup Frequent R&R. | Periodic replacement | $$ | Easy |
| Patient electrode gel Consumable. | Consumable | $ | Easy |
| Amplifier channel module | Periodic replacement | $$$ | Difficult |
| Stimulator cable | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.