Standard Chair Features Include U-prosthetic headrest Comfort Form arms (removable) Electric back with synchronized foot section Electric seat tilt Trendelenberg Position 610 electric base Corded remote foot controls w/ dismiss function ETL certified Dextrak Rail system Standard Choices Choice of any combination of two (2) removable Comfort Form arm with IV adapter pad or IV board Choice of upholstery colors.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Height / back / tilt does not respond to the hand or foot control.
Root cause: Foot / hand control fault, a linear actuator, a control-box relay, or a limit switch.
Symptoms: Table settles under load after positioning.
Root cause: Actuator backdrive or a gas-spring fault.
Symptoms: Intermittent or dead hand / foot control.
Root cause: Cable, contacts, or fluid ingress.
Symptoms: Rumble or sluggish travel on one or more functions.
Root cause: Worn actuator or unlubricated joints.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Linear actuator | Major service part | $$$ | Moderate |
| Hand / foot control | Periodic replacement | $$ | Fairly easy |
| Control box / relay | Major service part | $$$ | Moderate |
| Gas spring (back assist) | Major service part | $ | Moderate |
| Limit switch | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.