Datex Ohmeda · Model M-OSAT S/5 Oxygen Saturation Module
TruTrak+ is a powerful proprietary SpO2 enhancement technique that incorporates high speed data sampling, motion identification and quantification, and motion correction to directly track the patient’s saturation during conditions of clinical motion. Diagnostic plethysmographic waveform. Compatible with Datex-Ohmeda OxyTip®+ Sensors and Cables. Wide variety of SpO2 sensors for different applications. Adjustable pulse beep volume.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Agent, CO2, N2O, O2 or SpO2 values off vs a reference, calibration prompts.
Root cause: Sensor aging, a missed calibration, or the wrong calibration gas.
Symptoms: Host monitor does not display the module or pod.
Root cause: Docking / pod connector or cable fault.
Symptoms: Occlusion or water-trap alarm, no or low sample flow, flat waveforms.
Root cause: Full or expired water trap, or a blocked / kinked sample line.
Symptoms: Intermittent signal with cable movement.
Root cause: Worn patient cable.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set | Frequent wear item | $$ | Easy |
| Water trap / sample line | Consumable | $ | Easy |
| O2 sensor / gas bench service | Frequent wear item | $$ | Fairly easy |
| Module / pod docking connector | Major service part | $$ | Moderate |
| Internal sample pump | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Falsely high blood oxygen saturation readings in some circumstances could result in no alarm in a critical life-threatening situation.