Curlin Medical · Model PainSmart
Curlin’s PainSmart® IOD™- is communication-capable (connects with PCs or PDAs); sophisticated (high resolution, user audit trail, accurate, detailed information recording); and feature-rich (very large screen, shift-totals, on-screen hourly totals, highly visible large fonts, quick-repeat and continuous back-light-on with AC power). This unique, innovative device continuously monitors and displays line pressure, to help you detect potential catheter patency problems, such as occlusions, obstructions and pinched off catheters. PainSmart® IOD™ has the ability to deliver at low rates, a flow resolution that is up to 25 times better than any other ambulatory device on the market. It works in concert with PCs and/or Palm™ PDAs to reduce the risk of programming errors and improve the infusion outcome. These features, along with an extensive information database make PainSmart® IOD™ the device of choice, capable of significantly improving operating performance and safety, at a substantially reduced cost. Curlin offers a wide variety of accessories that allow users to enhance currently owned pumps or adapt them to new applications. This offering includes “hardware” such as pole mount clamps and many varieties of safety “shells” that prevent tampering and simplify the administration of narcotics. Many software packages are also available to expand a pump’s ability to deliver and monitor pain management and safeguard against accidental misprogramming.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The pump alarms and displays an error message / code and stops.
Root cause: A subsystem fault indexed in the service manual - motor / drive, a sensor, set-detection, or a board.
Symptoms: Repeated occlusion alarms, delivery stops, or an occlusion is missed.
Root cause: Kinked or clamped line, a closed roller clamp, a positional patient tube, pressure-sensor drift, or an improperly loaded set.
Symptoms: Frequent air-in-line alarms, delivery stops.
Root cause: Air in the set, an improperly loaded set, or an ultrasonic air-detector fault.
Symptoms: Delivered volume outside tolerance on the annual test, especially at low rates.
Root cause: Worn pumping mechanism / plunger drive.
Symptoms: Short run time, low-battery early after a full charge.
Root cause: Aged battery pack.
Symptoms: Set will not load, door will not latch, plunger grip poor.
Root cause: Worn door latch, plunger jaws, or anti-free-flow mechanism.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Pumping mechanism / rotor / plunger drive | Major service part | $$$ | Difficult |
| Pressure / air-detector sensor assembly | Major service part | $$ | Moderate |
| Door / latch / anti-free-flow assembly | Major service part | $$ | Moderate |
| Drive motor / gearbox | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.