• Curlin’s PainSmart® IOD™- is communication-capable (connects with PCs or PDAs); sophisticated (high resolution, user audit trail, accurate, detailed information recording); and feature-rich (very large screen, shift-totals, on-screen hourly totals, highly visible large fonts, quick-repeat and continuous back-light-on with AC power). This unique, innovative device continuously monitors and displays line pressure, to help you detect potential catheter patency problems, such as occlusions, obstructions and pinched off catheters. • PainSmart® IOD™ has the ability to deliver at low rates, a flow resolution that is up to 25 times better than any other ambulatory device on the market. It works in concert with PCs and/or Palm™ PDAs to reduce the risk of programming errors and improve the infusion outcome. These features, along with an extensive information database make PainSmart® IOD™ the device of choice, capable of significantly improving operating performance and safety, at a substantially reduced cost. • Curlin offers a wide variety of accessories that allow users to enhance currently owned pumps or adapt them to new applications. This offering includes “hardware” such as pole mount clamps and many varieties of safety “shells” that prevent tampering and simplify the administration of narcotics. Many software packages are also available to expand a pump’s ability to deliver and monitor pain management and safeguard against accidental misprogramming.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Occlusion alarm, no flow, upstream pressure high.
Root cause: Kinked set, clamped line, patient vein issue.
Symptoms: Air-in-line alarm, infusion paused.
Root cause: Air in set, improperly primed tubing.
Symptoms: Stalled infusion, inaccurate rate.
Root cause: Peristaltic motor or encoder wear.
Symptoms: Set not recognized, door-open error.
Root cause: Dirty or failed door microswitch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Common R&R on high-mileage pumps.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic roller / pump mechanism Common R&R on high-mileage pumps. | Periodic replacement | $$$ | Difficult |
| Air detector / ultrasonic sensor | Periodic replacement | $$ | Moderate |
| Door microswitch | Periodic replacement | $ | Fairly easy |
| Occlusion sensor assembly | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.