CME · Model BodyGaurd 121
• 2 Infusion Channel • Deliver 2 independent treatments at the same time. • 4 Infusion Programs • Flexible treatment capacity • High Accuracy ±5% • Flow Rates: 0.1 to 1200 mL/hr • Wide range for treatment flexibility. • Small, Lightweight, Battery Powered • Ideal fit within confines of transport vehicles. • Post-Occlusion Bolus Protection • Reduces line pressure after occlusion to prevent an accidental bolus when occlusion is resolved. • Free Flow Protection in Tubing Sets • Provides extra level of safety by preventing uncontrolled flow of fluid. • 3-Level Access Codes • Helps prevent accidental or unauthorized program changes. • Ultrasonic Air Sensor • Two levels of air bubble detection. • AC or Battery Powered • Flexibility to run off AC Power or rechargeable battery. • Uses Standard Medication Reservoirs • Flexibility to use medication bags, syringes, and bottles.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Occlusion alarm, no flow, upstream pressure high.
Root cause: Kinked set, clamped line, patient vein issue.
Symptoms: Air-in-line alarm, infusion paused.
Root cause: Air in set, improperly primed tubing.
Symptoms: Stalled infusion, inaccurate rate.
Root cause: Peristaltic motor or encoder wear.
Symptoms: Set not recognized, door-open error.
Root cause: Dirty or failed door microswitch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Common R&R on high-mileage pumps.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic roller / pump mechanism Common R&R on high-mileage pumps. | Periodic replacement | $$$ | Difficult |
| Air detector / ultrasonic sensor | Periodic replacement | $$ | Moderate |
| Door microswitch | Periodic replacement | $ | Fairly easy |
| Occlusion sensor assembly | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →