Biodex · Model Vasc Pro
Ergonomic design helps prevent musculoskeletal injuries – comfortable shoulder, arm and hand positions when scanning. Extra wide top with 500-lb patient capacity, suitable for bariatric patients. Reverse Trendelenburg to 30 degrees. Height range down to 23″ accommodates wheelchair transfers and those with ambulatory difficulties. Fowler positioning, 0-80 degrees, redesigned to accommodate natural body extension and sitting position without slide or shift. Motorized height, Fowler positioning, Trendelenburg and auto-level adjustment. Improved foot support with comfortable access to calves without crouching. Naugahyde®, antimicrobial mattress cover with Advanced BeautyGard® provides protection against bacteria. Central floor-locking system maintains table stability. Durable hand controller. Allows seated or standing work positions.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Height, tilt / Trendelenburg, back or the imaging drop-section does not respond to the foot or hand control.
Root cause: Foot / hand control fault, a linear actuator, a control-relay fault, or a limit switch.
Symptoms: Table settles under load after positioning.
Root cause: Actuator backdrive or a gas-spring fault.
Symptoms: Intermittent or dead foot / hand control.
Root cause: Cable, contacts, or fluid ingress.
Symptoms: The echo / vascular access window or pelvic tilt binds or will not lock.
Root cause: Worn drop-section pivot or lock.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Linear actuator | Major service part | $$$ | Moderate |
| Foot / hand control | Periodic replacement | $$ | Fairly easy |
| Control relay / board | Major service part | $$ | Moderate |
| Gas spring | Major service part | $ | Moderate |
| Drop-section / pelvic-tilt hardware | Major service part | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio