Bio-Rad Laboratories, Inc. · Model iMark
Fast microplate reading speeds Extensive onboard assay configuration Powerful data analysis capabilities Convenient built-in shaker Space-saving, wide-format internal thermal graphical printer Simplified standalone operation Compact, easy-to-use, and lightweight design Compatible with different types of 96-well microplates (flat, U-, V-bottom) and 8- or 12-well strip plates; maximum plate height: 16 mm Plate Compatibility: Compatible with standard 96-well microplates 128 mm L x 88 mm W Plate height cannot exceed 16 mm Clear flat-bottom plates are recommended such as Bio-Rad's Costar 96–Well Flat–Bottom EIA Plate (2240096) U-Bottom plates can be used, but V-bottom plates are not recommended.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Blank or standard absorbance off, poor plate-to-plate reproducibility, high CV.
Root cause: Lamp aging, a filter-wheel fault, or contamination on the optics / light path.
Symptoms: Plate not loading, jams, wells read at the wrong position, "plate error".
Root cause: Worn transport belt/motor, a position-sensor fault, or a V-bottom / oversized plate (max height 16 mm).
Symptoms: Shake step does not run or is uneven.
Root cause: Shaker drive fault.
Symptoms: No printout, faint print, jam.
Root cause: Worn print head or paper handling.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Lamp | Periodic replacement | $$ | Moderate |
| Filter wheel / interference filters | Major service part | $$ | Moderate |
| Plate transport belt and motor | Periodic replacement | $$ | Difficult |
| Plate position sensor | Periodic replacement | $ | Moderate |
| Thermal printer / paper | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.