Beckman Coulter · Model Optima MAX-XP
Quicker on the job - Optima MAX-XP offers faster speed, thanks to our new MLA-150 fixed angle rotor. It has a low k-factor for faster separation of subcellular particles, viruses, proteins and more. With the most efficient rotor available, you’ll reduce overall turnaround time and accelerate workflow. Reliability you can count on - As the world leader, Beckman Coulter is known for delivering the highest quality separation in the shortest time, day after day. We’ve leveraged over 60 years of proven centrifuge technology and made it available to you in this advanced benchtop design. Fits in anywhere - Designed for ultimate flexibility, Optima MAX-XP works well wherever you need it–from your personal lab space to a pedestal table. Keeping biosafety in mind, we made it small enough to fit inside a standard biosafety hood, yet so powerful it will boost efficiency. Makes everyone more comfortable - Optima MAX-XP operates so quietly, it won’t disturb coworkers. Pleasant instrument sounds with adjustable volumes alert you when your run is complete. And the ergonomically designed door handle can be easily opened with just one finger.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Error code, run will not begin, or aborts shortly after start.
Root cause: Set speed exceeds the rotor maximum, an imbalanced load, the lid / door not locked, an unapproved rotor, or a drive / control fault.
Symptoms: Slow spin-up, rumble, or vibration during a run.
Root cause: Load imbalance, worn drive / motor bearings, a worn drive coupling, or (older units) worn motor brushes.
Symptoms: Vacuum-fault alarm, long pump-down, run aborts.
Root cause: Vacuum-pump wear (low oil / worn vanes), a chamber / feed-through seal leak, or a valve fault.
Symptoms: Lid-lock error, will not open after a run, or will not lock to start.
Root cause: Lid-lock solenoid / switch fault, or a run still winding down.
Symptoms: Visible corrosion, cracks, or a bucket that will not swing; imbalance trips.
Root cause: Rotor / bucket ageing - a safety-critical wear item with a use-life limit.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Log rotor runs; retire per the manufacturer's rotor-life programme.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive / motor bearings & coupling | Major service part | $$$ | Difficult |
| Lid-lock solenoid / switch | Major service part | $$ | Moderate |
| Speed sensor / control board | Major service part | $$ | Moderate |
| Vacuum pump oil & O-ring kit | Periodic replacement | $$ | Moderate |
| Rotor / bucket set & O-rings Log rotor runs; retire per the manufacturer's rotor-life programme. | Major service part | $$$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.