Beckman Coulter · Model Microfuge16
• Presents a large, bright display with simple, intuitive push button key entry and automatic lid release at sample run completion • Processes a wide array of microcentrifuge tubes from 0.2 to 2.2 mL, with a choice of standard or soft start/stop programs • Brushless induction drive, safety auto-lock closure system and unique, air-cooled rotor bowl for years of safe, high-performing operation • Reduces process time with fast acceleration and deceleration rates • Offers added flexibility to your protocols with choice of pulse, timed or continuous runs • Maintenance-free rotor spins up to 14,800 rpm (16,163 x g). • Ideal for fast pelleting of DNA, RNA and proteins, and cell virus isolation. • Cold room compatible for flexibility with your protocols. • Is offered bundled with or without 24-place, autoclavable rotor for maximum sample throughput. • Compact to fit easily in the tightest of workspace environments
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.