Beckman Coulter · Model Airfuge Air-Driven
The easy-to-operate tabletop centrifuge: • Reaches top speed in as little as 30 seconds. • Decelerates smoothly to help keep sample contents separated. • Operates just a few degrees above ambient temperatures. • Offers run timed runs up to five hours, with hold position for long runs. The Airfuge CLS offers enhanced versatility with a variety of rotors: • Batch rotor pellets particles from a large sample. • Electron microscopy particle-counting rotor (EM-90) sediments particulates from very small volumes onto supports suitable for insertion into an election microscope. • Four fixed angle rotors (A-110; A-100/18; A-100/30; and A-95) generate the high speeds and forces necessary to perform a variety of tasks.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.