BD · Model Carefusion BD Alaris 8015
The Alaris 8015 PC Point-of-Care Unit (PCU) is the central core component of the popular Alaris System from CareFusion. It provides a common user interface for programming the various infusion and monitoring modules, which aids in reducing the complexity at the point of care. The Alaris 8015 is intended for adult, pediatric and neonatal care in the hospital and healthcare facility. This PCU helps optimize infusion therapy and patient care by using the Guardrails software to measure IV formula data. The Alaris 8015 in connection with the other Alaris System modules allows you to customize your infusion delivery. Overall, this Alaris IV pump assists in improving clinical practices and patient safety. The color display clearly communicates critical programming, infusion, monitoring and hospital-defined policy information. The wireless network card provides wireless communication capability between the Alaris System, Alaris Server, and Mobile Systems Manager. When it comes to the Alaris IV Pump system, Med One has a extensive in-house inventory to give you the best pricing, servicing and integration options to fit your facility.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The pump alarms and displays an error message / code and stops.
Root cause: A subsystem fault indexed in the service manual - motor / drive, a sensor, set-detection, or a board.
Symptoms: Repeated occlusion alarms, delivery stops, or an occlusion is missed.
Root cause: Kinked or clamped line, a closed roller clamp, a positional patient tube, pressure-sensor drift, or an improperly loaded set.
Symptoms: Frequent air-in-line alarms, delivery stops.
Root cause: Air in the set, an improperly loaded set, or an ultrasonic air-detector fault.
Symptoms: Delivered volume outside tolerance on the annual test, especially at low rates.
Root cause: Worn pumping mechanism / plunger drive.
Symptoms: Short run time, low-battery early after a full charge.
Root cause: Aged battery pack.
Symptoms: Set will not load, door will not latch, plunger grip poor.
Root cause: Worn door latch, plunger jaws, or anti-free-flow mechanism.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Pumping mechanism / rotor / plunger drive | Major service part | $$$ | Difficult |
| Pressure / air-detector sensor assembly | Major service part | $$ | Moderate |
| Door / latch / anti-free-flow assembly | Major service part | $$ | Moderate |
| Drive motor / gearbox | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.